What a Gloucester LEV test covers
LEV testing checks that your extraction still controls exposure to airborne contaminants as intended. For employers using it to control hazardous substances, thorough examination and testing is a legal requirement under the Control of Substances Hazardous to Health Regulations 2002. COSHH regulations set the general interval at least once every 14 months, or at the shorter interval in Schedule 4 for its specified processes. The Health and Safety Executive (HSE) guidance HSG258 describes a visual inspection, a review of technical performance and an assessment of control effectiveness. This covers the LEV system as it is used, including how employees position the hoods and carry out the work. Measurements alone need to be considered alongside those observations. Read the LEV testing regulations guide for the duty and shorter intervals.
Choose a competent person with relevant knowledge, skills and practical experience of LEV systems like yours. Give them your commissioning report, user manual, logbook and previous findings where available. These help establish how the LEV system should perform and whether it has changed. Tell the examiner about new processes, different materials or altered ductwork before the visit. Arrange safe access and discuss safety risks and how normal work can be observed during the examination. Ask for a written scope and a clear record of the results, including defects and the action needed. Keep that record, or a suitable summary, available for at least five years from the date it was made. Read the findings and act on them. To support a compliant workplace, maintain effective control between visits and record routine checks and repairs. The LEV testing cost guide explains what to include when asking companies to price the work.
Testers covering Gloucester
Discuss testing standards using HSG258 and ask for evidence of any BOHS P601 qualification claimed. LevHQ does not verify qualifications or certify listed testers as compliant.
Cotswold LEV Systems
Gloucester
3 miles away
Based in Gloucestershire, with over 20 years of experience dealing with LEV systems and powder and bulk systems. Design, supply and install compliant LEV soluti...
CDI Facilities Ltd
Newent
8 miles away
Facilities Management providing: Water Hygiene Management Compliance Legionella Control, LEV Testing and services, Kitchen, Canopy & Duct Cleaning, Noise at Wor...
HSL Compliance Ltd
Ross-on-Wye
14 miles away
HSL Compliance can provide LEV assessments in accordance with HSG258 utilising BOHS P601 qualified occupational hygienists. COSHH regulations state that all LEV...
Airmec Essential Services
Bristol
26 miles away
Airmec Essential Services is an independent air and water hygiene specialist. We save lives by ensuring workplaces and public buildings throughout the UK remain...
Get three quotes for Gloucester
Tell us how many systems you have and we send your request to the three nearest testers.
Request quotesNearby
LEV testing questions for Gloucester
How many LEV testers are listed near Gloucester?
This page lists 4 testers within 50 km of Gloucester. Check with each company that it covers your workplace.
How far do the listed testers near Gloucester travel?
The testers listed near Gloucester have service radii of 80 km from their own locations. Confirm travel to your postcode directly with the tester.
How often is LEV testing required in Gloucester?
COSHH regulations set the general interval at least once every 14 months, or at the shorter interval in Schedule 4 for its specified processes.