How an LEV system works
You may hear it called an LEV system, LEV extraction, dust extraction or fume extraction. HSE heads its LEV pages "workplace fume and dust extraction". The job is the same in every case: take the contaminant out of the air before it reaches the person doing the work.
A system can be a tiny hood built into a hand-held tool or a booth big enough to walk into. A process such as sanding, welding or spraying releases the contaminant at a point called the source. A fan pulls air into the hood, ducting carries it away, an air cleaner removes the contaminant if the system has one, and the discharge releases the air somewhere safe.
HSG258, the HSE guide to LEV, says most systems, but not all, have the five parts below. It adds that you should identify everything that works as part of the system. That can include a machine casing or guard that helps extraction, a flue from a furnace or oven, and any system that supplies replacement (make-up) air.
Contaminated air Cleaned air
| Part | What it does | What HSE says can go wrong |
|---|---|---|
| Hood | The place where the contaminant cloud enters the system. | It does not catch or contain the cloud. |
| Ducting | Carries air and contaminant from the hood to the discharge. | Settled material narrows the duct and cuts airflow. |
| Air cleaner | Filters or cleans the extracted air. Not every system needs one. | Filters deteriorate with use and need replacing. |
| Air mover | Usually a fan, the engine that powers extraction. | Run outside its best operating range, it is noisier, uses more power and can overload, leading to system failure. |
| Discharge | Releases the extracted air to a safe place. | Air released somewhere unsafe, or a poor stack design. HSG258 chapter 7 covers it. |
Why the hood matters most
HSE says that when LEV does not work as well as it should, a common reason is that the hood does not catch or contain the contaminant effectively. HSG258 paragraph 88 says hood selection and design are critical and must match the process, the source, production and the way the operator works.
HSG258 paragraph 94 gives three ways to judge a hood. How much does it hold back the cloud? How well does the airflow carry the cloud into the system? How little of the cloud reaches the operator's breathing zone?
Hoods fall into three types. Enclosures are always more effective than capturing or receiving hoods (paragraph 97).
| Type | How it works | Examples |
|---|---|---|
| Enclosing | The process sits inside the hood, wholly or with openings for material or the operator. | Glove box, paint-spraying cabin, walk-in booth, fume cupboard. |
| Receiving | The process is outside. The hood receives a cloud already moving towards it. | Canopy over a hot process, push-pull system. |
| Capturing | The process is outside. The hood must pull the cloud in. It is the most common type. | Rim extraction, downdraught table, on-tool extraction. |
The principles of LEV
HSG258 paragraph 100 sets out the general principles of hood design and application. These decide whether LEV works.
- Enclose the process and its source as far as you can. The more it is enclosed, the more likely the LEV is to work.
- Put capturing and receiving hoods as close to the source as possible.
- Position the hood to use the speed and direction of the air leaving the source.
- Match the hood size to the process and the size of the cloud.
- Keep the cloud away from the worker's breathing zone as far as possible.
- Keep swirling air (eddies) inside the hood to a minimum.
- Fit the hood to the way the worker really does the job, and try it out with the people who use it.
What LEV is used for
The right hood depends on how the contaminant behaves once it leaves the process. HSE's process and source videos make that visible with smoke and a dust lamp. These are examples from HSE.
| Process | What the contaminant does | What HSE shows or says |
|---|---|---|
| Hot process such as a furnace or oven | Rises as a plume. | A canopy hood above it. It does not work on cold processes and does not protect someone working above the heat. |
| Grinding wheel or circular saw | The spinning blade or wheel acts as a crude fan and throws a jet along its rotation. | A receiving hood, large enough and close enough to catch the jet. |
| Hand sanding of wood | Fine dust that cannot be seen in normal light. | On-tool extraction. HSE uses a dust lamp to show the cloud. |
| Welding | Fume is released at the weld. | HSE shows a conventional capture hood, a high vacuum nozzle and on-torch extraction. |
| Spray painting | A narrow jet leaves the spray gun at over 100 metres a second and can travel over 12 metres. | The cloud is energetic and hard to control. HSG258 lists paint-spraying cabins as room enclosures. |
When LEV is not the right control
HSE says to consider other options first where reasonably practicable. Examples are changing the method of work, replacing the material with a safer one, reducing the size of the source, or fitting lids to equipment.
HSG258 paragraph 241 says LEV might not suit many widely spaced sources, a source too large to cover, a source that moves, a source that emits little contaminant, or a contaminant that is offensive but not harmful. Do not assume a standard design works either. Paragraph 93 notes that some bench-mounted fan and filter units used for solder fume are ineffective.
LEV and general ventilation
General ventilation replaces contaminated air across a space with cleaned or fresh air. Dilution (mixing) and displacement are two forms of it. LEV extracts the contaminant at the source instead. HSG258 says an employer may use LEV for the main sources and general ventilation for minor ones.
Dilution relies on the contaminant spreading evenly through the room. HSG258 paragraph 243 says that assumption is common but usually wrong, because there are some areas of high concentration, usually near the sources.
The two work together in one way. Air taken out by LEV has to be replaced. Without planned make-up air, HSG258 paragraph 237 warns of severe draughts that may compromise the effectiveness of the LEV.
General ventilation: the cloud spreads through the room before fresh air thins it. The air is usually most contaminated near the source, where the worker stands.
LEV: the hood takes the cloud away at the source, so less of it reaches the worker's breathing zone.
Airflow indicators
HSE says one of the main reasons LEV stops doing its job is that airflow falls, for example through material building up or ducting being damaged. An airflow indicator at the hood is the only method HSE knows of that shows the operator straight away when this happens.
The simplest is usually a manometer, a gauge on the hood duct that shows static pressure. HSE's example of a simple display is green for adequate airflow and red for inadequate. More hazardous work may call for a pressure switch that sets off an alarm if flow drops below a set level. HSG258 notes that alarms can fail without warning, so their testing frequency should be set in the user manual.
You cannot judge hood airflow by hand, and HSE says paper or plastic tell-tales do not give an effective indication. HSE confirms there is no specific legal requirement to fit airflow indicators. It does recommend them in HSG258 and tells employers to make sure LEV has them or an equivalent.
Green: adequate airflow
Signs your LEV is not working
HSE's daily checklist for LEV users, on pocket card INDG409, doubles as a list of warning signs. Some contaminants are invisible, so a clear-looking workplace does not prove the air is clean.
Tick each sign once you have checked for it today.
Cleaning and upkeep
COSHH regulation 9 requires an employer who provides LEV as a control to keep it in efficient working order, in good repair and in a clean condition. INDG408 groups the work by kind of part: moving parts that wear, such as fan bearings and filter shakers; fixed parts such as hoods, ductwork and seals, which can suffer physical or chemical damage; parts that deteriorate with use, such as filters and flexible ducting; and items that need regular attention, such as filter replacement or removing sludge from a wet scrubber.
Ducts carry contaminant, and some of it settles. HSG258 paragraph 177 says settled particles narrow the duct, raise resistance and cut airflow. They are hard to pick up again, can block the duct and, with flammable material, create a fire risk. Paragraph 176 names long horizontal runs, low points, and the points after junctions and bends as particular problems.
Filters are cleaned by mechanical shaking, reverse airflow or pulse-jet. They also wear out. The designer should specify a replacement interval, which HSG258 paragraph 207 says is normally between one and four years. Wet systems need attention too. HSG258 says self-induced spray collectors need regular cleaning to avoid bacterial infection and bad smells, and there may be a legionella risk.
If the LEV can become contaminated with toxic substances, INDG408 says you may need permits to work and formal method statements when people work on it. Record checks, maintenance, replacements and repairs in the logbook. INDG408 suggests keeping the logbook for at least five years.
For checks between tests, read our guide on how often LEV testing is required. LevHQ also has a free LEV log book template.
Buying or changing LEV
HSE says many employers buy LEV and find it does not work. This may be because it is the wrong type or because it is not properly installed or maintained. INDG408 sets out this sequence to avoid that.
The INDG408 sequence for buying LEV
-
Remove or reduce the source
Work out which jobs and activities cause exposure, and whether the source can be removed or reduced first.
Step 1 of 6 -
Write a specification
Describe the process, the contaminant, its hazards and the sources, and how tight the control needs to be. Ask for airflow indicators, equipment that is easy to use, check, maintain and clean, and training from the supplier.
Step 2 of 6 -
Choose a competent supplier
The employer is responsible for this. INDG408 suggests inviting more than one tender, asking for site visits and asking how each supplier will prove the LEV controls exposure.
Step 3 of 6 -
Have it commissioned
Commissioning takes place while normal work is going on. It shows the LEV was installed properly and controls exposure, and it gives the benchmark for later tests.
Step 4 of 6 -
Get the documents and train people
Ask for a user manual, a logbook and a commissioning report. Train the people who use it.
Step 5 of 6 -
Recommission after changes
If the process or layout changes after commissioning, have the LEV recommissioned. The guide on how often LEV testing is required explains when that applies.
Step 6 of 6
Finding a supplier
LevHQ is a directory. Its LEV design and installation companies page lists businesses that say they offer those services. Check each profile yourself and ask the questions above. LevHQ does not design, install or test LEV, or approve any company.
LEV, the law and testing
COSHH requires employers to control the risks from hazardous substances. HSE says LEV may help you do that. Our guide to LEV testing regulations sets out the duties in order, including the Northern Ireland rules.
Once LEV is installed as a control, a competent person must thoroughly examine and test it at least every 14 months, or more often for four processes listed in COSHH Schedule 4. The guides below explain the test, the dates and the visit.
Where to go next
This guide covers what LEV is and how to recognise a working system. Each of these goes deeper on one question.
| Question | Where to look |
|---|---|
| Which regulations apply | LEV testing regulations |
| What the test involves | What is LEV testing? |
| How long a system can go untested | How often is LEV testing required? |
| What the visit involves | What happens during an LEV test? |
| The HSE guide to LEV, chapter by chapter | HSG258 explained |
| Keeping a record of checks | Free LEV log book template |
| Finding a company to design or fit a system | LEV design and installation companies |
| Dust and fume extraction suppliers | Dust and fume extraction companies |
| Finding a company to test your system | LEV testing companies in the UK |
Check what you know
4 quick questions from this guide. Nothing you choose is saved or sent.
-
Show the answer
An enclosing hood. HSG258 paragraph 97 says enclosures are always more effective than capturing or receiving hoods.
-
Show the answer
Read an airflow indicator such as a manometer. HSE says an airflow indicator is the only method it knows of that shows this straight away. A hand or a paper tell-tale does not give an effective indication.
-
Show the answer
Planned make-up air to replace it. HSG258 paragraph 237 warns that without planned make-up air there can be severe draughts that may compromise the LEV.
-
Show the answer
Every one to four years. HSG258 paragraph 207 says the designer should specify a replacement interval, normally between one and four years.
Questions duty holders ask
What are the principles of LEV?
HSG258 sets out general principles for hood design and application. Enclose the process as far as you can, put capturing and receiving hoods close to the source, match the hood size to the cloud, keep the cloud away from the worker's breathing zone and fit the hood to how the job is really done.
What is the difference between LEV and general ventilation?
LEV extracts a contaminant at or near its source. General ventilation replaces contaminated air across the whole space with cleaned or fresh air. HSG258 says the common assumption that contaminant spreads evenly through a workplace is usually wrong, because there are some areas of high concentration, usually near the sources.
Do I have to fit an airflow indicator to LEV?
HSE says there is no specific legal requirement to fit airflow indicators. You still have to keep the system working properly. An indicator is the only method that shows the operator straight away if airflow drops, and HSG258 recommends them. Feeling the air with your hand does not work.
Is it UK law to have ventilation in a working office?
Yes. Regulation 6 of the Workplace (Health, Safety and Welfare) Regulations 1992 in Great Britain, and of the 1993 Northern Ireland version, requires every enclosed workplace to be ventilated by a sufficient quantity of fresh or purified air. Plant used for this must warn of failure where health or safety needs it. That is general ventilation, not LEV.
When is LEV not the right control?
HSG258 says LEV might not suit many widely spaced sources, a source too large to cover, a source that moves, one that emits little contaminant, or a contaminant that is offensive but not harmful. HSE also says to consider removing or reducing the source before you install LEV.
Is your next test due?
Put in the date of the last test and get the deadline, with a reminder if you want one.
LEV test due date calculatorUse the directory to find an LEV tester near you.
Find LEV testing companies
Browse LEV testing companies across the UK, or choose a region.
- LEV testing in East Midlands
- LEV testing in East of England
- LEV testing in London
- LEV testing in North East
- LEV testing in North West
- LEV testing in Northern Ireland
- LEV testing in Scotland
- LEV testing in South East
- LEV testing in South West
- LEV testing in Wales
- LEV testing in West Midlands
- LEV testing in Yorkshire and the Humber
Sources
- HSE: HSG258, Controlling airborne contaminants at work, opened 7 November 2026
- HSE: INDG408, clearing the air, a simple guide to buying and using LEV, opened 7 November 2026
- HSE: INDG409, LEV pocket card for workers, opened 7 November 2026
- HSE: local exhaust ventilation, workplace fume and dust extraction, opened 7 November 2026
- HSE: commission your LEV system, opened 7 November 2026
- HSE: LEV information for employers, opened 7 November 2026
- HSE: common processes and sources, opened 7 November 2026
- HSE: frequently asked questions about LEV, opened 7 November 2026
- Legislation.gov.uk: COSHH regulation 9, maintenance, examination and testing, opened 7 November 2026
- Legislation.gov.uk: COSHH Schedule 4, shorter test intervals, opened 7 November 2026
- Legislation.gov.uk: Workplace (Health, Safety and Welfare) Regulations 1992, regulation 6, opened 7 November 2026
- Legislation.gov.uk: Workplace (Health, Safety and Welfare) Regulations (Northern Ireland) 1993, regulation 6, opened 7 November 2026