From the directory
Face fit testing in figures
Counted from the companies listed on this page. Services and qualifications are as each company states them. LevHQ does not verify them.
- List face fit testing
- 15
- Name qualitative testing
- 6 of 15
- Name quantitative testing
- 9 of 15
- Say testers are Fit2Fit accredited
- 4 of 15
- Also list LEV testing
- 13 of 15
Method and Fit2Fit counts come from what each company's own website said on 16 November 2026.
Find the right company
Companies by region
Featured listings come first, then Listed, then Free. Companies in the same group are in A to Z order.
- East Midlands (2)
- East of England (2)
- North West (4)
- South East (3)
- Wales (1)
- West Midlands (2)
- Yorkshire and the Humber (1)
Face fit testing companies in the East Midlands
2 companies based in or near the East Midlands
Integral HSE
Mansfield
Integral HSE's LEV engineers cover identifying a need for LEV, performance specification for new systems, LEV design, commissioning and managing systems already...
- Face fit testing
- LEV testing
- LEV design
- LEV installation
- +4 more
Validate Consulting
Chesterfield
Here at Validate Consulting Ltd, we work to protect employees from health hazards in the workplace - such hazards include harm caused by loud noise, exposure to...
- Face fit testing
- LEV testing
- Training
- Workplace air monitoring
Face fit testing companies in the East of England
2 companies based in or near the East of England
AEC is an employee-owned compliance consultancy and training organisation providing occupational hygiene, asbestos testing, water hygiene, fire safety, LEV...
- Face fit testing
- Training
- Workplace air monitoring
- LEV testing
Element
Luton
Luton laboratory is one of the UK’s leading MCERTS and UKAS accredited (EA "approved") stack emissions testing facilities. In addition, we offer occupational...
- Face fit testing
- Training
- Welding fume
- Workplace air monitoring
Face fit testing companies in the North West
4 companies based in or near the North West
Airborne Environmental Consultants Ltd (AEC)
Manchester
AEC is an employee-owned compliance consultancy and training organisation providing occupational hygiene, asbestos testing, water hygiene, fire safety, LEV...
- Face fit testing
- Training
- Workplace air monitoring
- LEV testing
Stockport laboratory is one of the UK’s leading MCERTS and UKAS accredited (EA "approved") stack emissions testing facilities. In addition, it offers...
- Face fit testing
- Training
- Welding fume
- Workplace air monitoring
OHEC
Manchester
OHEC - Experienced and friendly Occupational Hygiene and Environmental Consultants. UKAS accredited asbestos surveys, asbestos air testing, bulk sample...
- Face fit testing
- LEV testing
- Fume extraction
- Workplace air monitoring
- +1 more
Velocity Safety
Blackburn
Velocity Safety provides fire protection, workplace safety testing, equipment inspection and calibration services from Blackburn, supporting organisations...
- Face fit testing
- Dust extraction
- LEV testing
- Spray booth
- +1 more
Face fit testing companies in the South East
3 companies based in or near the South East
UKAS-accredited laboratory and head office in Fareham, Hampshire, with a Bristol regional hub supporting on-site services across the South West. Comprehensive...
- Face fit testing
- LEV testing
- Workplace air monitoring
- Training
Gully Howard Technical
Portsmouth
We can carry out LEV testing for you, as well as offering LEV training.
- Face fit testing
- LEV testing
- LEV design
- LEV servicing
- +4 more
Health Partners Group
Wealden
Helping people be their best
- Face fit testing
- LEV testing
- Workplace air monitoring
- Training
Face fit testing companies in Wales
1 company based in or near Wales
ESP Environmental Ltd
Llanelli
Family run asbestos and occupational hygiene surveyors. Asbestos Surveys Air Quality Monitoring Legionella Risk Assessments Water Sampling LEV Noise at Work...
- Face fit testing
- LEV testing
- Workplace air monitoring
Face fit testing companies in the West Midlands
2 companies based in or near the West Midlands
Eagle Safety & Environment Ltd
Welshpool
Occupational Health & Safety Consultancy, specialising in Legionella, Noise, HAV, Workplace air quality testing, LEV assessments. Fire risk assessments,...
- Face fit testing
- LEV testing
- Training
- Workplace air monitoring
Synergy Environmental Solutions Limited
Stoke-on-Trent
Synergy Environmental Solutions are trusted specialists in workplace health, safety, and regulatory compliance. We offer expert support across all aspects of...
- Face fit testing
- Dust extraction
- LEV testing
- Welding fume
- +1 more
Face fit testing companies in Yorkshire and the Humber
1 company based in or near Yorkshire and the Humber
Sysco Environmental Ltd
Barnsley
UK occupational health, safety and environmental monitoring. Workplace exposure, air quality, noise, hazardous materials and boundary monitoring.
- Face fit testing
- LEV testing
- LEV design
- LEV installation
- +3 more
Checked on their websites
What each company's website says
LevHQ read each company's own website on 16 November 2026. The table gives the test methods the website names and whether it says its testers are Fit2Fit accredited.
| Company | Methods its website names | Fit2Fit | Source |
|---|---|---|---|
| Integral HSEMansfield Listed among its occupational hygiene services. | Not stated | Not stated | Its website, checked 16 November 2026 |
| Validate ConsultingChesterfield | Not stated | Not stated | Its website, checked 16 November 2026 |
| Airborne Environmental Consultants Ltd (AEC)Brentwood Company-wide page. It does not name this office. | Quantitative | Not stated | Its website, checked 16 November 2026 |
| ElementLuton Group-wide page covering its UK and Ireland offices. It does not name this office. | Quantitative | Not stated | Its website, checked 16 November 2026 |
| Airborne Environmental Consultants Ltd (AEC)Manchester Company-wide page. It does not name this office. | Quantitative | Not stated | Its website, checked 16 November 2026 |
| Element Stockport Environmental Testing LaboratoryStockport Group-wide page covering its UK and Ireland offices. It does not name this office. | Quantitative | Not stated | Its website, checked 16 November 2026 |
| OHECManchester | Qualitative | Not stated | Its website, checked 16 November 2026 |
| Velocity SafetyBlackburn | Qualitative and quantitative | Says its testers are accredited | Its website, checked 16 November 2026 |
| Envirochem Analytical Laboratories LtdFareham | Quantitative | Says its testers are Fit2Fit-qualified | Its website, checked 16 November 2026 |
| Gully Howard TechnicalPortsmouth | Quantitative | Says its testers are accredited | Its website, checked 16 November 2026 |
| Health Partners GroupWealden | Qualitative | Not stated | Its website, checked 16 November 2026 |
| ESP Environmental LtdLlanelli | Qualitative | Not stated | Its website, checked 16 November 2026 |
| Eagle Safety & Environment LtdWelshpool | Not stated | Not stated | Its website, checked 16 November 2026 |
| Synergy Environmental Solutions LimitedStoke-on-Trent | Qualitative and quantitative | Says its testers are accredited | Its website, checked 16 November 2026 |
| Sysco Environmental LtdBarnsley | Qualitative and quantitative | Says its testers are accredited | Its website, checked 16 November 2026 |
LevHQ lists the services each company says it offers. LevHQ does not confirm accreditation. Check any tester on Fit2Fit's register.
The basics
What fit testing is
Fit testing checks that a tight-fitting facepiece matches the wearer's face and seals adequately to it. HSE says a competent person should carry out the test.
HSE says the approved codes of practice for COSHH and other regulations stipulate fit testing when tight-fitting respiratory protective equipment (RPE) is chosen. HSE's guide INDG479 says:
A fit test should be carried out as part of the initial selection of the RPE.
HSE, INDG479, Guidance for employers
HSE says competence can be shown by accreditation under the Fit2Fit scheme, which HSE supports. It adds:
The scheme is not compulsory and employers are free to take other action to comply with the law.
HSE, INDG479, Introduction
INDG479 Table 1
Which method suits which mask
Qualitative fit testing (QLFT) is a pass/fail test based on the wearer’s subjective assessment of any leakage through the face seal region by detecting the introduction of bitter- or sweet-tasting aerosol as a test agent.
HSE, INDG479, Qualitative fit testing
Quantitative fit testing (QNFT) provides a numerical measure of how well a facepiece seals against a wearer’s face; this is called a fit factor.
HSE, INDG479, Quantitative fit testing
The method depends on the mask. INDG479 Table 1 shows which methods apply. BA means breathing apparatus.
| RPE and facepiece | Quantitative: ambient particle counting | Quantitative: controlled negative pressure | Qualitative: taste |
|---|---|---|---|
| Disposable respirator, half mask | Yes | No | Yes |
| Reusable respirator, half mask | Yes | Yes | Yes |
| Reusable respirator, full-face mask | Yes | Yes | No |
| Powered respirator, half mask | Yes | Yes | Yes |
| Powered respirator, full-face mask | Yes | Yes | No |
| Constant flow airline BA, half mask | Yes | Yes | Yes |
| Constant flow airline BA, full-face mask | Yes | Yes | No |
| Fresh air hose BA, half mask | Yes | Yes | Yes |
| Fresh air hose BA, full-face mask | Yes | Yes | No |
| Demand valve BA, half mask | Yes | Yes | Yes |
| Demand valve BA, full-face mask | Yes | Yes | No |
| Escape BA, full-face mask | Yes | Yes | No |
Every full-face mask in the table needs a quantitative method. For controlled negative pressure, any leakage through the exhalation valve has to be eliminated. For FFP1 and FFP2 disposable masks, the particle counting instrument may need extra functionality.
Powered or constant-flow airline RPE with a loose-fitting hood or helmet does not need fit testing. Tight-fitting powered or constant-flow airline RPE still does.
Repeat tests
When to test and retest
Fit test each type of tight-fitting facepiece a person wears, as part of choosing it. INDG479 says:
A fit test should be repeated whenever there is a change to the RPE type, size, model or material, or whenever there is a change to the circumstances of the wearer that could alter the fit of the RPE
HSE, INDG479, Guidance for employers
Its examples of changes to the wearer include weight loss or gain, substantial dental work, facial changes or piercings, and a change of other head-worn PPE. INDG479 sets no fixed interval. It says it is good practice to have a system to review when a repeat fit test may be needed.
Preparing the wearer
Before the test
Inform wearers that they should be clean-shaven in the region of the face seal whenever they wear a tight-fitting facepiece at work.
HSE, INDG479, Preparing the wearer
Wearers should wear any other PPE that could interfere with the fit of the facepiece during the test. Before a qualitative test, wearers should not eat, drink (except still, unflavoured water), smoke or chew gum for at least 30 minutes. Before an ambient particle counting test, they should not smoke, including e-cigarettes, for at least 60 minutes. Before a qualitative test, the tester first checks that the wearer can taste the test aerosol. This is often called a sensitivity test.
Keeping the result
What the fit test record should show
INDG479 Annex 1 lists what the fit test report should identify, where applicable. This includes the wearer's name, the facepiece make, model, material and size, the filters fitted, any spectacles and other PPE worn, the test exercises and method, the fit factors for a quantitative test, the pass level, the pass or fail result, the date and the details of the person who did the test. The report should be available to the employee.
Where masks fit in
How it relates to LEV
INDG479 assumes the employer has chosen tight-fitting RPE as part of its control regime, after an appropriate risk assessment. HSE's LEV guide, HSG258, describes local exhaust ventilation (LEV) as an engineering control system to reduce exposures to airborne contaminants such as dust, mist, fume, vapour or gas.
Read what local exhaust ventilation is, look up a substance in the workplace exposure limits table and use the COSHH assessment template.
A practical guide
Questions to ask a fit testing company
Which method suits our masks?
Give the make, model, size and type of each facepiece. INDG479 Table 1 shows that a full-face mask needs a quantitative method.
How do your testers show competence?
HSE says Fit2Fit accreditation is one way. Check any accreditation on Fit2Fit's register.
How should wearers prepare?
Ask about being clean-shaven where the mask seals, other head-worn PPE and the 30 minutes before a taste test.
What will the report show?
Ask for the details INDG479 lists, including the facepiece, the method, the result and the tester.
What happens if a wearer fails?
INDG479 says to try an alternative make, model or size. Where no adequate fit is possible, it says to choose RPE that does not rely on a tight face seal, such as a loose-fitting hood or helmet.
Related company lists: LEV servicing and maintenance companies, spray booth servicing and testing companies, workplace air monitoring companies, dust and fume extraction companies and LEV design and installation companies.
Face fit testing questions
What is a face fit test for?
It checks whether a tight-fitting facepiece seals adequately against the individual wearer’s face.
How much does a face fit test cost?
LevHQ does not list prices. For a quote, tell the company the number of wearers, the masks they use and whether you need a site visit.
Is it a legal requirement to have a face fit test?
HSE says the approved codes of practice for several regulations stipulate that tight-fitting RPE should be fit tested as part of selection.
How long do face fit tests last?
INDG479 sets no fixed interval. Repeat when the facepiece changes or circumstances affecting its fit change. INDG479 says it is good practice to have a system to review when a repeat fit test may be needed.
What is the difference between qualitative and quantitative fit testing?
Qualitative testing uses the wearer’s response to a taste. Quantitative testing measures a numerical fit factor. Full-face masks need a quantitative method.
Need your LEV tested as well?
The quote form is for LEV testing, not face fit testing. Tell us how many systems you have and we send your request to up to three testers who list LEV testing and cover your site. Paid listings come first, then the nearest.
Request LEV testing quotesSources
Opened and checked on 16 November 2026.