DSEAR: the short answer
DSEAR requires employers to assess risks from dangerous substances at work. They must eliminate or reduce those risks so far as reasonably practicable.
What DSEAR stands for
DSEAR stands for the Dangerous Substances and Explosive Atmospheres Regulations 2002, SI 2002/2776. HSE leaflet INDG370 says dangerous substances could, if not properly controlled, cause harm to people "as a result of a fire, explosion or similar incident". The HSE DSEAR page also includes harm from corrosion of metal.
What is a dangerous substance?
Regulation 2 defines dangerous substances by their properties and the work or conditions in which they are present. The hazard can be fire, explosion or similar harmful physical effects, or being corrosive to metals.
HSE examples include solvents, paints, varnishes, flammable gases, liquefied petroleum gas (LPG), dusts from machining and sanding, and dusts from foodstuffs.
What employers must do
HSE summarises the employer duties as follows.
Select a duty to see more.
-
Identify risks
Find dangerous substances and assess their risks.
Item 1 of 5 -
Control risks
Remove risks or control them, and reduce the effects of incidents.
Item 2 of 5 -
Plan for emergencies
Prepare plans and procedures for accidents, incidents and emergencies.
Item 3 of 5 -
Inform and train
Ensure employees have information and training to control or deal with risks.
Item 4 of 5 -
Classify areas
Identify and classify areas where explosive atmospheres may occur, and avoid ignition sources there.
Item 5 of 5
The DSEAR risk assessment
Regulation 5 requires a suitable and sufficient assessment when a dangerous substance is present or liable to be present. Consider its properties, supplier information, quantities, processes, interactions, handling, storage and transport.
Consider maintenance, existing and planned controls, the likelihood and duration of explosive atmospheres, ignition sources and the scale of a fire or explosion. Include connected places and other necessary safety information.
Review the assessment regularly, particularly after significant changes or if it may no longer be valid. Employers with five or more employees must record significant findings as soon as practicable, including the measures taken or planned.
The order for removing or reducing risk
Regulation 6 requires employers to eliminate or reduce risk so far as reasonably practicable. Prefer substitution with a substance or process that eliminates or reduces the risk.
If risk cannot reasonably be eliminated, apply suitable controls and measures to reduce the effects of a fire or explosion. The regulation orders controls by priority, starting with reducing the quantity and avoiding or minimising releases.
Further controls include controlling releases at source, preventing explosive atmospheres and avoiding ignition sources. HSE describes this as a hierarchical approach.
The six hazardous area zones
Employers classify places where hazardous explosive atmospheres may occur. The zones describe how often and how long an explosive atmosphere is likely to be present.
| Zone | What it means | Applies to |
|---|---|---|
| Zone 0 | Explosive atmosphere present continuously, for long periods or frequently. | Gas, vapour or mist mixed with air |
| Zone 1 | Explosive atmosphere likely to occur occasionally in normal operation. | Gas, vapour or mist mixed with air |
| Zone 2 | Explosive atmosphere unlikely in normal operation, but if it occurs, persists for a short period only. | Gas, vapour or mist mixed with air |
| Zone 20 | Explosive atmosphere present continuously, for long periods or frequently. | Cloud of combustible dust in air |
| Zone 21 | Explosive atmosphere likely to occur occasionally in normal operation. | Cloud of combustible dust in air |
| Zone 22 | Explosive atmosphere unlikely in normal operation, but if it occurs, persists for a short period only. | Cloud of combustible dust in air |
ATEX equipment and zoned areas
Zoned areas must be protected from ignition sources. HSE says equipment and protective systems for them should meet the Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016.
Those regulations put Directive 2014/34/EU into effect in Great Britain. HSE calls the equipment and protective systems it covers "ATEX" equipment.
Where necessary, entrances to zoned areas must carry the specified EX sign. Workers need appropriate clothing that does not create an ignition risk through electrostatic discharge.
Before a workplace with zoned areas is first used, a competent person or organisation must verify its overall explosion safety.
Dust and extraction systems
HSE lists dusts from machining, sanding and foodstuffs among dangerous substances. HSE guidance HSG103 covers the safe handling of combustible dusts.
HSE WIS32 says wood dust should not escape collection systems and build up in workrooms. An explosion in a collection unit can disturb settled dust and cause a secondary explosion. It also says ductwork needs regular internal inspection and cleaning.
| Need | Where to look |
|---|---|
| Understand wood dust | Wood dust extraction guide |
| Find extraction companies | Dust and fume extraction companies |
DSEAR and COSHH
COSHH covers ill health from hazardous substances. DSEAR covers harm from fire, explosion and similar incidents.
The HSE COSHH leaflet INDG136 says clouds of dust from everyday materials, such as wood dust or flour, can explode if ignited. It adds that it does not deal with flammability or explosion hazards, and it points readers to the HSE DSEAR leaflet INDG370.
This means one dusty process can need a COSHH assessment for health and a DSEAR assessment for fire and explosion.
Where to go next
Use these resources for extraction and related duties. The related guides below cover COSHH, wood dust and the hierarchy of control.
| Need | Where to look |
|---|---|
| Read about COSHH | COSHH regulations |
| Understand wood dust | Wood dust extraction |
| Find extraction companies | Dust and fume extraction companies |
| Find servicing | LEV servicing and maintenance companies |
| Find an LEV tester | LEV testing companies |
| Choose controls in order | Hierarchy of control |
| Read hazard labels | COSHH symbols |
Check what you know
3 quick questions from this guide. Nothing you choose is saved or sent.
-
Show the answer
20, 21 and 22. Zones 20, 21 and 22 cover clouds of combustible dust in air.
-
Show the answer
Substitution. Regulation 6 gives preference to substitution that eliminates or reduces risk.
-
Show the answer
Before first use. The employer must ensure overall explosion safety is verified before first use.
Questions duty holders ask
What is a DSEAR risk assessment?
It assesses risks to employees from dangerous substances present or liable to be present at work. Regulation 5 lists what the employer must consider, including ignition sources and the potential effects of a fire or explosion.
What does DSEAR stand for?
DSEAR stands for the Dangerous Substances and Explosive Atmospheres Regulations 2002. They require employers to eliminate or reduce risks from dangerous substances so far as reasonably practicable.
When did DSEAR come into force?
Most regulations came into force on 9 December 2002. Regulations 15(2) and 16(2) followed on 5 May 2003. Regulations 5(4)(c), 7, 11 and 17(1) to (3) came into force on 30 June 2003.
What is a zone 0 hazardous area?
Zone 0 is one of the six zones in Schedule 2. It is a place where gas, vapour or mist mixed with air forms an explosive atmosphere. That atmosphere is present continuously, for long periods or frequently.
Does DSEAR apply to dust?
Yes. Combustible dust can form an explosive atmosphere in air. DSEAR zones 20, 21 and 22 describe places where such dust clouds may occur.
Is your next test due?
Put in the date of the last test and get the deadline, with a reminder if you want one.
LEV test due date calculatorUse the directory to find an LEV tester near you.
Find LEV testing companies
Browse LEV testing companies across the UK, or choose a region.
- LEV testing in East Midlands
- LEV testing in East of England
- LEV testing in London
- LEV testing in North East
- LEV testing in North West
- LEV testing in Northern Ireland
- LEV testing in Scotland
- LEV testing in South East
- LEV testing in South West
- LEV testing in Wales
- LEV testing in West Midlands
- LEV testing in Yorkshire and the Humber
Sources
How this guide was made: LevHQ wrote this guide from the sources listed below and checked it on 18 November 2026. AI tools helped draft and check the text.
- DSEAR 2002, SI 2002/2776, revised text, opened 18 November 2026
- DSEAR 2002: regulation 1, opened 18 November 2026
- DSEAR 2002: regulation 2, opened 18 November 2026
- DSEAR 2002: regulation 5, opened 18 November 2026
- DSEAR 2002: regulation 6, opened 18 November 2026
- DSEAR 2002: regulation 7, opened 18 November 2026
- DSEAR 2002: Schedule 2, opened 18 November 2026
- HSE: Dangerous substances and explosive atmospheres, opened 18 November 2026
- HSE: COSHH basics, overview, opened 18 November 2026
- HSE: Working with substances hazardous to health, a brief guide to COSHH, INDG136, revised 10/12, opened 18 November 2026
- HSE: ATEX equipment and explosive atmospheres, opened 18 November 2026
- HSE: Controlling fire and explosion risks in the workplace, INDG370 (rev1), 01/13, opened 18 November 2026
- HSE: Safe handling of combustible dusts, HSG103, 2003, opened 18 November 2026
- HSE: Safe collection of woodwaste, WIS32, 2011, opened 18 November 2026