LEV testing directory and reports for the UK

The basics

Wood dust extraction: what HSE expects, machine by machine

HSE says to fit extraction at woodworking machines to capture and remove dust before it can spread. The exposure limits are 3 mg/m3 for hardwood dust and 5 mg/m3 for softwood dust, and a competent person must examine the extraction at least every 14 months.

Published 16 November 2026

hardwood dust exposure limit
3 mg/m3
softwood dust exposure limit
5 mg/m3
maximum gap between examinations
14 months
minimum vacuum class HSE names for cleaning
Class M

Wood dust extraction: the short answer

Fit local exhaust ventilation (LEV) at woodworking machines to capture dust before it spreads. Keep it working and have a competent person examine it at least every 14 months.

Why wood dust matters

HSE's WIS23 says wood dust can cause asthma, dermatitis and irritation to the eyes, nose and throat. HSE says carpenters and joiners are four times more likely to develop asthma than other UK workers.

Hardwood dust can cause cancer, particularly of the nose. Settled dust contains fine particles likely to damage the lungs.

HSE says a suitable health surveillance programme helps find health effects early. It should cover all workers who might breathe in wood dust. HSE says to seek advice from an occupational health professional, a doctor or nurse with experience of woodworking health risks.

Wood dust exposure limits

The hardwood dust workplace exposure limit is 3 mg/m3. The softwood dust limit is 5 mg/m3. Both are eight-hour time-weighted averages.

For a mixture of hardwood and softwood, the 3 mg/m3 hardwood limit applies to all wood dust in the mixture.

HSE says control of wood dust is adequate when the eight principles of good control practice in COSHH Schedule 2A are applied, exposure is below the relevant limit, and exposure is reduced as low as is reasonably practicable.

Check the exposure limits
SubstanceWhere to look
Hardwood dustHardwood dust exposure limit
Softwood dustSoftwood dust exposure limit

Extraction machine by machine

Choose a machine to see a summary of its HSE sheet. Read the sheet for the full guidance, including respiratory protection.

HSE extraction advice for woodworking machines
MachineWhat HSE says the extraction should doHSE sheet
BandsawCapture dust at the source, usually low down at the rear of the casing. If inadequate, consider under-table extraction or a movable hood.WD1
Circular bench sawExtract at the crown guard and under the bench. Enclose the space under the bench to capture emitted dust.WD2
Cross-cut sawExtract at the top guard and a hood behind the saw. If the blade cuts through the bench, fit an under-bench hood.WD3
Vertical spindle moulderDraw chips and dust away with hoods behind the cutter guard, behind the fence and above the motor.WD4
RoutersEnclose and extract CNC flat-bed and overhead fixed router heads. Fit hand-held routers with on-tool extraction, a transparent viewing panel and brush seal.WD5
Hand-held powered sanderUse on-tool extraction with a Class M or H unit. Connect the hose securely and align the holes in extracted sanding discs.WD7
Wall sawExtract around the blade. Account for blade movement driving dust horizontally along the backboard.WD10
Surface planerEnclose and extract the cutter beneath the working surface to capture dust.WD11
Fixed narrow-belt sanderEnclose the sanding surface as far as possible and use extraction. On large horizontal belt sanders, enclose both pulleys with extraction hoods.WD12
Fixed disc sanderFit an extracted ring-shaped hood around the disc. Extraction through the worktable can improve control.WD13
Fixed drum or bobbin sanderExtract around the sanding drum. A hood that encloses more of the drum controls dust more effectively.WD14
Chop sawExtract at the top guard and through a hood behind the saw. Design the hood for the size of the pieces being cut.WD15

Designing extraction for your workshop

Tell the designer how many machines need extraction, their types, the workshop layout and which machines run together.

Get the airflow, connection sizes or volume flow rates for each machine connection from the machine manufacturer or an experienced body.

A disc sander beside a perforated downdraught table connected to an extraction duct.
A downdraught table beside a disc sander.

Checking extraction works

Airflow indicators show whether airflow is adequate. They help operators spot problems such as closed dampers or blockages.

A dust lamp can reveal airborne dust that is normally invisible. Used correctly, it helps identify leaks and check whether extraction is effective.

Follow the extraction manufacturer's maintenance guidance and train workers to use the system properly.

Cleaning up wood dust

Use a suitable industrial vacuum cleaner rated at least Class M. Never sweep or use compressed air, which disturbs dust and allows it to be inhaled.

HSE also describes a suction hose attachment connected to an extraction system for cleaning floors. Its WD17 sheet gives the equipment details.

Fire and explosion

Wood dust collection systems can present fire and explosion risks. HSE's WIS23 says air cleaners should, where possible, be outside, away from thoroughfares and other work areas.

HSE's WIS32 says dust should not escape from collection systems and build up in workrooms, because an explosion in a collection unit can stir up settled dust and cause a secondary explosion that is usually more destructive than the first. It says ductwork needs regular internal inspection and cleaning.

Fire and explosion duties
Read more
Read the DSEAR guide for fire and explosion duties.

Masks as well as extraction

HSE's WIS23 says that if a risk of breathing wood dust remains after effective extraction, which is usually the case for sawing, routing and sanding, respiratory protective equipment (RPE) is also required. It is also required for short jobs such as cleaning and maintenance.

HSE's machine sheets say to provide RPE with an assigned protection factor of at least 20. WIS23 says suitable disposable respirators are often described as FFP3, and that nuisance dust masks give no protection against wood dust.

HSE says to make sure a mask fits properly by having it face fitted and by being clean shaven.

Testing and records

Have a competent person thoroughly examine and test the extraction at least every 14 months. HSE's WIS23 says most LEV systems need a thorough examination and test once each year, and that the law allows 14 months between tests.

HSE's machine sheets say to keep an employer record of each thorough examination and test for at least 5 years, and to keep records of checks.

Testing and records
NeedWhere to look
Record checksFree LEV log book
Find a testerLEV testing companies

Where to go next

Find a company or read more about LEV.

Related LevHQ pages
NeedWhere to look
Find an extraction companyDust and fume extraction companies
Get masks fit testedFace fit testing companies
Check workplace limitsWorkplace exposure limits
Understand extractionWhat is local exhaust ventilation?
Plan the next testHow often is LEV testing required?
Prepare for a visitWhat happens during an LEV test?

Check what you know

3 quick questions from this guide. Nothing you choose is saved or sent.

  1. Which limit applies to a mixture of hardwood and softwood dust?
    Show the answer

    3 mg/m3. The hardwood limit applies to all wood dust in the mixture.

  2. What is the maximum gap between examinations?
    Show the answer

    14 months. A competent person must examine the extraction at least every 14 months.

  3. What minimum vacuum class does HSE name for cleaning?
    Show the answer

    Class M. HSE says to use a suitable industrial vacuum cleaner rated at least Class M.

Questions duty holders ask

How can I remove dust from wood?

Capture dust at the machine with suitable extraction before it spreads, and clean settled dust with an industrial vacuum rated at least Class M. HSE's WIS23 lists using compressed air lines to blow dust off furniture and other articles before spraying as something to avoid.

What are the different types of dust extraction systems?

HSE's machine sheets describe on-tool extraction for hand-held sanders and routers, hoods at machine guards and casings, and enclosures such as an under-bench enclosure on a circular saw. The right arrangement depends on the machine.

Is a dust extractor better than a vacuum cleaner?

They do different jobs. Extraction at the machine captures dust as it is made. For cleaning, HSE says to use an industrial vacuum of at least dust class M, or a suction hose attached to the extraction system, which HSE's WD17 sheet describes.

How can wood dust be prevented?

HSE suggests reducing the need for sanding by cutting and shaping components more accurately. Capture dust produced at machines with effective extraction.

How often does wood dust extraction need testing?

A competent person must thoroughly examine and test it at least every 14 months. Maintain and check it between examinations.

Is your next test due?

Put in the date of the last test and get the deadline, with a reminder if you want one.

LEV test due date calculator

Use the directory to find an LEV tester near you.

Find LEV testing companies

Browse LEV testing companies across the UK, or choose a region.

Sources

How this guide was made: LevHQ wrote this guide from the sources listed below and checked it on 16 November 2026. AI tools helped draft and check the text.

Read next